Even with continual technological advances in materials, water continues to create unnecessary problems. This is most often due to an envelope’s inability to act as an integrated system, preventing water and pollutant infiltration. All too often, several systems are designed into a building, chosen independently and acting independently rather than cohesively.

Detailing transitions from one system to another or terminations into structural components are often overlooked. Product substitutions that do not act integrally with other specified systems create problems and leakage. Inadequate attention to movement characteristics of a structure can cause stress to in-place systems that they are not able to withstand.

All these situations, acting separately or in combination, will eventually cause water intrusion.

To understand the complete enveloping of a structure, several definitions, as well as their relationship to one another, must be made clear:

Roofing

That portion of a building that prevents water intrusion in horizontal or slightly inclined elevations. Although typically applied to the surface and exposed to the elements, roofing systems can also be internal, or sandwiched, between other building components.

Below-Grade Waterproofing

Materials that prevent water under hydrostatic pressure from entering into a structure or its components. These systems are not exposed or subjected to weathering, such as by ultraviolet rays.

Above-Grade Waterproofing

A combination of materials or systems that prevent water intrusion into exposed structure elements. These materials are not subject to hydrostatic pressure but are exposed to weathering and pollutant attack.

Dampproofing

Materials resistant to water vapor or minor amounts of moisture that act as backup systems to primary waterproofing materials. Dampproofing materials are not subject to weathering or water pressure.

Flashing

Materials or systems installed to redirect water entering through the building skin back to the exterior. Flashings are installed as backup systems for waterproofing or dampproofing systems.

Building Envelope

The combination of roofing, waterproofing, dampproofing, and flashing systems that act cohesively as a barrier, protecting interior areas from water and weather intrusion. These systems envelop a building from top to bottom, from below grade to the roof.

The entire exterior building skin must be enveloped to prevent water infiltration. Buildings must be made waterproof from roof coverings to vertical above-grade walls to below-grade floors.

The Building Envelope: How Individual Systems Work Together

An envelope may contain combinations of several systems, such as a building’s facing material (e.g., brick facade), a water repellent, a cavity wall dampproofing, and a through-wall flashing. Each system acts integrally with the others as a total system for complete effectiveness as a weather-tight building envelope.

Figure 1.1 shows the interrelationships of various waterproofing systems.

Figure 1.1: Detailing of the Building Envelope

Original figure labels transcribed below:

  • Coping Cap
  • Dampproofing
  • Masonry with Repellent
  • Waterproofing
  • Counterflashing
  • Roofing Membrane
  • Weep Hole
  • Shelf Angle
  • Flashing
  • Through-Wall Flashing
  • Reglet
  • Sealant
  • Below-Grade Waterproofing with Protection Board
  • Waterstop

In Figure 1.1, horizontal membrane roofing terminates into a vertical parapet at the metal counterflashing. Parapet wall waterproofing also ties into roofing at this counterflashing. This flashing detail ensures envelope watertightness. It ties two separate systems together so that they may act cohesively.

A similar detail occurs at the coping cap. This flashing details terminations of parapet waterproofing, building facing material, clear water repellent on brick, and cavity wall dampproofing. Without such critical detail, the independent systems mentioned above could not function cohesively to provide building envelope watertightness.

On the vertical facade, detailing control joints with sealant at the brick facade allows for thermal movement while maintaining a watertight joint. The brick has through-wall flashing diverting intruding water, collected by dampproofing, back out through weep holes. Additionally, sealant at window perimeters acts as a transition between brick facing and window frames.

Dampproofing terminates into below-grade waterproofing at a reglet placed into the concrete wall. Sealant acts as a transition between these systems. Waterstops tie vertical waterproofing to horizontal slab waterproofing, completing a watertight seal.

Drainage systems then channel collected water at foundations to prevent unnecessary water pressure against a building foundation wall.

As shown, each separate waterproofing material effectively joins together to form the building envelope.

The Importance of Proper Transitions and Terminations

Each trade contractor’s work, regardless of its being thought of as waterproofing, must become part of a totally watertight building envelope.

Equally important, all individual envelope systems must be adequately transitioned into other components or provided with watertight terminations.

Often, the tradesworkers completing this work are not aware, trained, or supervised in envelope waterproofing. The resulting improper attention to details is responsible for countless problems in construction.

Properly detailing a building’s envelope presents an enormous task. From inception to installation, numerous stumbling blocks occur.

Highlighting this interrelationship of various envelope systems is the following principle:

As much as 90 percent of all water intrusion problems occur within 1 percent of the total building exterior surface area.

The 1 percent of a structure’s facade contains the terminations and transition detailing that all too frequently lead to envelope failures.

Not until our ability to train and supervise field construction reaches the technology of waterproofing systems and construction techniques will this situation correct itself.

It is not the actual manufactured waterproofing systems or envelope systems that leak, but the field construction details of terminations and transitions.

Additional Benefits of Building Waterproofing

Besides preventing water infiltration, waterproofing systems prevent structural damage to building components.

In northern climates, watertightness prevents spalling of concrete, masonry, or stone due to freeze-thaw cycles. Watertightness also prevents rusting and deterioration of structural or reinforcing steel encased in exterior concrete or behind masonry facades.

Waterproofing also prevents the passage of pollutants that cause steel deterioration and concrete spalling, such as chloride ions (salts), into structural components. This is especially true in horizontal exposed areas such as balcony decks and parking garages.

Prevention of acid rain contamination (sulfites mixing with water to form sulfuric acid) and carbon acids (vehicle exhaust and carbon dioxide that forms carbonic acid when mixed with water) is also an important consideration when choosing proper waterproofing applications.

Energy Efficiency and Environmental Control

Building envelopes also provide energy savings and environmental control by acting as weather barriers against wind, cold, and heat.

Additionally, envelopes must be resistant to wind loading and wind infiltration. These forces, in combination with water, can multiply the magnitude of damage to a structure and its interior contents.

Direct wind load pressure can force water deeper into a structure through cracks or crevices, where water might not normally penetrate. It also creates vertical upward movement of water over window sills and through vents and louvers.

Air pressure differences due to wind conditions may cause water that is present to be sucked into a structure because of negative pressure in interior areas.

This situation occurs when outside air pressure is greater than interior air pressure. It also occurs through a churning effect, where cool air is pulled into lower portions of a building, replacing warmer air that rises and escapes through higher areas.

To prevent this forced air infiltration and associated energy loss, a building envelope must be resistant and weather-tight against wind.

What Is Required for an Effective Building Envelope?

For envelopes to function as intended requires proper attention to:

  1. Selection and design of compatible materials and systems.
  2. Proper detailing of material junctions and terminations.
  3. Installation and inspection of these details during construction.
  4. Ability of composite envelope systems to function during weathering cycles.
  5. Maintenance by building owners.

From the numerous systems available to a designer, specific products that can function together must be chosen.

Once products are chosen and specified, proposed substitutions by contractors must be carefully reviewed. Similar products may not function or be compatible with previously chosen components. Substitutions with multiple systems of specified components only further complicate matters.

Improper attention to specified details of terminations, junctures, and changes in materials during installation can cause water infiltration.

Once construction begins, installation procedures must be continually monitored to meet specified design criteria and manufacturers’ recommendations.

Detailing problems compound by using several different crafts and subcontractors in a single detail.

For instance, a typical coping cap detail involves roofing, carpentry, masonry, waterproofing, and sheet metal contractors. One weak or improperly installed material in this detail will create problems for the entire envelope.

Finally, products chosen and installed as part of a building envelope must function together during the life cycling and weathering of a structure.

Proper maintenance after system installation is imperative for proper life cycling.

Consider the following questions:

  • Will shelf angles be adequate to support parapet walls during wind or snow weathering?
  • Will oxidation of counterflashing allow water infiltration into a roof system, causing further deterioration?

From these processes of design, construction, and maintenance, 99 percent of a building envelope will typically function properly. It is the remaining 1 percent that creates the magnitude of problems.

This 1 percent requires much more attention and time by owners, architects, engineers, contractors, and subcontractors to ensure an effective building envelope.

Common Causes of Building Envelope Failures

The most frequent problems within this 1 percent occur because of inadequate design detailing by architects, improper installation by contractors, and improper maintenance by owners.

Typical frequent errors include:

Architects and Engineers

  • Improper detail specifications.
  • No allowance for structural or thermal movement.
  • Improper selection of materials.
  • Use of substitutes that do not integrate with other components of the envelope.

Contractors and Subcontractors

  • Improper installations.
  • Inattention to details.
  • Lack of coordination between subcontractors.
  • Use of untrained mechanics to complete the work.

Building Owners and Managers

  • No scheduled maintenance programs.
  • Use of untrained personnel to make repairs.
  • No scheduled inspection programs.
  • Postponement of repairs until further damage is done.

Testing, Material Compatibility, and Quality Assurance

The chapters in this book review each component of a waterproofing envelope in detail. They are followed by a chapter on bringing individual systems together for a watertight building envelope.

In addition to the information presented, standard test results completed in accordance with the National Bureau of Standards (NBS) (Federal Standards) and the American Society for Testing and Materials (ASTM) are referred to.

These results from standardized tests allow comparison of various materials and systems to ensure that proper envelope materials are chosen for a particular installation. Refer to Chapter 10 for information on testing.

Testing also allows material selection that ensures compatibility with other integral envelope systems.

Remember, no matter how good a material is chosen, a building envelope will succeed only if all components act as a cohesive unit.

One weak detail on an envelope can cause the entire system to fail.

darathPr0Activ3

Share
Published by
darathPr0Activ3

Recent Posts

Redlining of Deck Edge Glass Rail Embedded Shoe

Complex Detailing to HideRecessed shoe railing at Deck Edge can be Challenging  Incorrect detailing will…

1 month ago

Results of Systems Approach vs. Improper Waterproofing Approach within New Construction

Result of Systems ApproachBuilding science has delivered overwhelming improvement in health, safety and durability of…

1 month ago

(SAM) Self-Adhered Membranes, Flashings and WRB’s

What does Self-Adhered Really Mean? Background of SAM’s / otherwise known as SAF (Self-Adhered Flashings)…

3 months ago

Building Structural Analysis

A building's structural integrity is the foundation of everything else: safety, longevity, performance, and value.…

5 months ago

Building Failure Investigation

When a building fails, whether through water intrusion, structural deterioration, envelope breakdown, or material defects,…

5 months ago

CA Consultants Barry Taheri Presenter at AIA East Bay Symposium

CA Consultants Principal, Barry Taheri was a presenter at the AIA East Bay Symposium on…

1 year ago