What does Self-Adhered Really Mean?

Background of SAM’s / otherwise known as SAF (Self-Adhered Flashings)

  1. Highly utilized waterproof / water-resistant material that brings the advantages of adhesion to dry sheet goods.
  2. This material has evolved into becoming a staple within the construction industry, today widely used in all aspects of the building enclosure system.
  3. SAMs are often mis-applied to the point where their performance and functionality (watertightness) is often compromised (wrinkles, inadequate substrate, lack of support and poor-to-no adhesion).
  4. The most important thing to remember is that unlike its name, (SAM) is anything but self-adhering (see pictures below).

4 EXAMPLES OF POOR INSTALLATION OF SAM

  • #1 Lack of adhesion, no primer, not rolled
  • #2 Wrinkles, voids, unsupported
  • #3 No primer, poor adhesion
  • #4 Unsupported, bridging air gap

For the material (SAM’s) to function properly, it must be fully adhered. Some common mistakes that we have seen are shown in the four pictures on the previous page:

  1. Unsupported substrate (bridging air or gaps).
  2. Substrate is not recognized by the manufacturer. Substrate is too soft or too rough or chemically incompatible for adhesion.
  3. Rolling requirement step is often overlooked (via laminate roller), which would be a problem because the adhesive within the SAM is pressure activated.
  4. The substrates are often not a true plane — free of debris, dust, offsets, voids and gaps.
  5. Primer is often overlooked to perpetuate adhesion (specifically on porous substrates). Please note SAM may only be applied to primer during primer’s tack time (typically 5-to-15-minute window).

If and only WHEN the above aspects are correctly addressed, the (SAM) will then function to the performance of its water-resistant capacity.

A much more forgiving material that is starting to take over the self-adhered membrane applications are the liquid-applied applications of the equivalent and comparable sheet-good materials. The reason that liquid-applied is much more forgiving is because it is painted on and fully adheres without requiring a pressure-activated adhesive.

It is this firm’s opinion that the industry will progressively move toward more liquid-applied applications for waterproofing of the envelope and enclosure system rather than dry sheet goods and/or self-adhered membranes. Specifiers and Architects, consider upgrading complex geometry projects to liquid-applied application within the Division 7 Specifications.

darathPr0Activ3

Recent Posts

Redlining of Deck Edge Glass Rail Embedded Shoe

Complex Detailing to HideRecessed shoe railing at Deck Edge can be Challenging  Incorrect detailing will…

1 month ago

Results of Systems Approach vs. Improper Waterproofing Approach within New Construction

Result of Systems ApproachBuilding science has delivered overwhelming improvement in health, safety and durability of…

1 month ago

Building Structural Analysis

A building's structural integrity is the foundation of everything else: safety, longevity, performance, and value.…

5 months ago

Building Failure Investigation

When a building fails, whether through water intrusion, structural deterioration, envelope breakdown, or material defects,…

5 months ago

CA Consultants Barry Taheri Presenter at AIA East Bay Symposium

CA Consultants Principal, Barry Taheri was a presenter at the AIA East Bay Symposium on…

1 year ago

Los Angeles Waterproofing Professionals

When it comes to protecting your valuable investment from Los Angeles' unique climate challenges, selecting…

1 year ago